Buy ASME N TESTING OF NUCLEAR AIR-TREATMENT SYSTEMS from SAI Global. Find the most up-to-date version of ASME N at Engineering Periodically certain actions of the ASME N Committee will be published as ASME is the registered trademark of The American Society of Mechanical.

Author: JoJogal Kazrakasa
Country: Bosnia & Herzegovina
Language: English (Spanish)
Genre: Relationship
Published (Last): 15 May 2013
Pages: 89
PDF File Size: 15.63 Mb
ePub File Size: 17.96 Mb
ISBN: 345-3-58764-418-5
Downloads: 23431
Price: Free* [*Free Regsitration Required]
Uploader: Dill

Answer to Question #10654 Submitted to “Ask the Experts”

Yes, there are accepted procedures that are used for testing the integrity of HEPA filters used in vacuum cleaners. The tests involve introducing a known concentration of aerosol particles of an acceptable size into the inlet of the vacuum cleaner and measuring the concentration of the aerosol particles as they exit in the exhaust.

These measurements will confirm whether or not the HEPA filter s is performing according to specifications. You can get an idea of the kind of setup that is suitable by looking at this description at a Brookhaven National Laboratory site. In order to perform such a test, one must have available an aerosol generator that produces the desired size distribution of particles.

ANSI/ASME N Testing Workshop

The standard material used in the past and still widely used has been an oily substance called dioctyl phthalate DOP. Concerns with possible carcinogenicity of the DOP has led some individuals and groups to use alternative materials such as nontoxic polyolefin oils.

By blowing air through small nozzles into a reservoir of the oil or by using other means, such as thermal generation in which the heated oil recondenses to form small droplets, the desired aerosols are generated. The aerosol concentrations are measured using an appropriate particle counter, a specialized device adme provides a means, often a light scattering process, for determining the concentration of airborne particulates of the size range of interest that pass through the device.

  IEC 60906-1 PDF

ASME N test results for Savannah River Site AACS filter co..|INIS

You can find a variety of information on aerosol generators and aerosol counters for use in filter testing by searching the Internet. As awme general practice, testing of the filters should be done when the vacuum cleaner is purchased this validation is often provided by the manufacturerwhenever the HEPA filter s is changed, whenever anything has happened that leads you to believe the filter integrity may have been compromised, azme otherwise on an annual basis as long as the vacuum cleaner is available same use.

There is a significant investment of money and time required to obtain the necessary equipment and become proficient in its use. If this is not practical, you may want to consider having a service company that deals with such assessments do the work for you, especially if the vacuum cleaner is not used frequently.

You can also find a variety of other sources that discuss the process and recommendations regarding filter testing. These are not aimed specifically at testing of xsme cleaners, but the principles and many of the recommendations are applicable.

A good reference to review such sources is a book by R. The book deals with many aspects of testing and evaluation of air particulate cleaning systems, including specific references to HEPA vacuum cleaners, as can be seen from the Table of Contents available at the above link.

  IMR 26650 PDF

FLANDERS CSC TECHNOLOGIES

George ChabotPhD. Join or Renew Members Only. Instrumentation and Measurements The following question was answered by an expert in the appropriate field: I am interested in information regarding the calibration of vacuums, for example, high-energy particulate air HEPA systems. These vacuum cleaners are used for decontamination of loose particulates from equipment and personnel.

The limit for HEPA is Answer posted on 24 April The information posted on this web page is intended as general reference information only. Specific facts and circumstances may affect the applicability of concepts, materials, and information described herein.

The information provided is not a substitute for professional advice and should not be relied upon in the absence of such professional advice. To the best of our asms, answers are correct at the time they are posted. Be advised that over time, requirements could change, new data could be made available, and Internet links could change, affecting the correctness of the answers.

Answers are the professional opinions of the expert responding to each question; they do not necessarily represent the position of the Health Physics Society.

Software